{"product_id":"premium-40-amp-30ma-1pn-rcbo","title":"Premium 40 Amp 30mA 1P+N 2Mod Type A RCBO with High-Performance Short-Circuit Capacity and Electro-Magnetic Design","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThis Premium RCBO (Residual Current Breaker with Overcurrent) features a robust electro-magnetic design, making it suitable for various electrical applications. With a rated current of 40A and a residual current of 30mA, this device provides reliable protection against electrical faults and ensures safety in your installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Electro-magnetic type\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResidual Current Characteristics:\u003c\/strong\u003e A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePole Number:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Short-Circuit Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 20\/40A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 240V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Residual Operating Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping Duration:\u003c\/strong\u003e Instantaneous - 0.1s\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectro-Mechanical Endurance:\u003c\/strong\u003e 4000 cycles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Terminal:\u003c\/strong\u003e Pillar terminal with clamp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Capacity:\u003c\/strong\u003e Rigid conductor 16mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection Height:\u003c\/strong\u003e 21.5mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDimensions \u0026amp; Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color:#f8f9fa; border-bottom:2px solid #dee2e6;\"\u003e\n      \u003cth style=\"padding:12px; text-align:left; border:1px solid #dee2e6;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px; text-align:left; border:1px solid #dee2e6;\"\u003eMeasurement\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003eShort-Circuit Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003eTripping Duration\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003e0.1s\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003eElectro-Mechanical Endurance\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #dee2e6;\"\u003e4000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the purpose of an RCBO?\u003c\/strong\u003e An RCBO is designed to protect against both earth faults and overcurrent, ensuring safety in electrical systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow does the tripping duration affect performance?\u003c\/strong\u003e A shorter tripping duration, such as 0.1s, allows for quick disconnection in case of a fault, which enhances safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan this RCBO be used in residential applications?\u003c\/strong\u003e Yes, it is suitable for both residential and commercial installations, providing essential protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Industrialsafety-UK.co.uk","offers":[{"title":"Default Title","offer_id":57269786050944,"sku":"EVNS_IS23","price":62.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1070\/9034\/files\/2a6546fbd476fc50b981a2ac438a4ca5.png?v=1768901797","url":"https:\/\/www.industrialsafety-uk.co.uk\/products\/premium-40-amp-30ma-1pn-rcbo","provider":"Industrialsafety-UK.co.uk","version":"1.0","type":"link"}